Web Analytics Made Easy - StatCounter

Fastener Item Tenders

Get complete information related to latest Fastener Item Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fastener Item Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fastener Item Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

corporations/Associations/Others

CTN :43502529 Due date: 06 Feb, 202606 Feb, 2026 NA
Tender For corrigendum : supply of routine and breakdown maintenance works of aph -replacement of heating element.when the elements strips are to be dismantled and cleaned with wire brush. , servicing and minor repairing of flue gas primary air and secondary air inlet, outlet and inter connecting dampers of aph. flue gas dampers. , servicing and minor repairing of flue gas primary air and secondary air inlet, outlet and inter connecting dampers of aph.primary air damper , servicing and minor repairing of flue gas primary air and secondary air inlet, outlet and inter connecting dampers of aph.secondary air damper , servicing of flue gas primary air and secondary air inlet, outlet and inter connecting dampers of aph flue gas dampers. , servicing of flue gas primary air and secondary air inlet, outlet and inter connecting dampers of aph primary air damper , servicing of flue gas primary air and secondary air inlet, outlet and inter connecting dampers of aph secondary air damper , repairing of flue gas, sa, pa inlet and outlet duct manholes cover. , repairing flue gas dampers flaps. , repairing of pa damper flaps. , repairing of sa damper flaps. , repairing of semi circular baffle. , repairing of distance pieces in fg duct. , repairing expansion joints before and after air pre heater. , cleaning of cooling water line of lubricating oil pumps of aph by cutting and welding. , repairing of hangers of sector plate. , decoupling and re-coupling of electrical motor for replacement of electric plate and fluid coupling etc. , fabrication of bracket 1 set equal to one no. in board and one no. in outboard bracket. , replacement of brackets. , leveling of rotor. , water washing and cleaning of flue gas duct sa duct. , providing sealing cover on expansion joints. , repairing of t-bars. , replacement and repairing of fg duct by cutting and welding. , adjustment of axial seal plate. , complete replacement of the static seal of aph , re- visioning or repairing of air seal housing of guide bearing of aph. , alignment of electric motor and air motor with reduction gear box of air pre-heater. , replacement of gear box of air pre heater. , cleaning of water washing nozzle, elbow and socket. , repairing of oil or water valve lube oil system of size 25mm. to 40mm. , replacement of oil or water valve lube oil system of size 25mm. to 40mm. , servicing or overhauling of over running clutch system of aph. , checking of gear box of aph. , cleaning or servicing of support bearing and their housing. , repairing and reconditioning of centre section surface beneath guide bearing and casting the refractory. , leveling of sector plates of hot end or cold end. , replacement or reversal of he ie ce basket aph. , hot washing of air pre heater. , cleaning of air pre heater through nozzle. , round the clock checking and routine maintenance of air pre heaters of unit no 12 and 13 btps, obra , round the clock checking and routine maintenance of air pre heaters of unit no 9,10,11 btps, obra

State Government

CTN :43718297 Due date: 07 Feb, 202607 Feb, 2026 NA
Tender For procurement of tungsten carbide coated distance pieces between feedgate and grinder required during unit aoh at ahp, 3x660 mw, ktps, koradi.

Central Government/Public Sector

CTN :43655605 Due date: 19 Feb, 202619 Feb, 2026 NA
Tender For 25 kv earthing/discharge rod assembly for high rise ohe with working voltage 25 kv ac traction with top clamp (suitable for 36 to 50 mm bus bar and also suitable for 10 to 20 mm dia. conductor) . pole made of cast resin or resin-bonded glass fibre, coated with three coats of poly- urethane, the discharge /earthing pole assembly shall have an overall length of not less than 7.5 meters in five equal sections. single core flexible multi strand annealed copper cable should have double insulation, a cross section of 40 sq mm of size 248/0.45 mm and 14 meter long cable (specification is: 1554 (pt. i)- 1988 and is 2071 (pt. 1 and iii). with earthing double clamp drg. no. eti/ohe/sk/482 or latest (each discharge rod is to be supplied with 02 nos. earting clamps), insulated tee junction- insulated tee junction drg no. eti/ohe/sk/481 and re/33/p/530 or latest (the cable should have an insulated tee junction and the tee clamp should be of brass covered in clamp casing of ebonite material). and whole assembly to be supplied in rugged canvas bag and all shall be as per rdso specification no. eti/ohe/51 (9/87) with latest a and c slip no. 1 (10/92) or latest , and additional part required with each discharge rod to be supply. (1) 01 nos. insulated tee junction. (2) 01 nos. top clamp made of copper suitable for 36 to 50 mm bus bar and also suitable 10 -20 mm dia conductor, (3) 01 nos. spare earthing clamp and. (4) special instruction- 1. discharge rod cable lugs should be made of copper. 2. the cable should have double insulation, a cross- section of 40 sq mm, and 248/0.45 mm strands. 3. the discharge rod should be strong enough to prevent swaying or breaking during maximum extension. every nut and bolt used in the discharge rod must include a washer and spring washer to ensure secure fastening. 5. after the award of the p.o., the firm must ensure approval of one sample of the discharge rod from the consignee before rites inspection. 6. the length of cable from the earthing clamp to top clamp shall not be less than 12.5 mtr. in the cable an insulated tee junction shall be provided at a distance of about 3.5 mtr from the earthing clamp. from this insulated tee junction another piece of cable not less than 1.50 m long shall be provided at the end of which other earthing clamp shall be provided. 7. the galvanized steel tube (threaded) used for coupling of pieces of discharge rod should be at least 20 cm or more as required to prevent swaying of pole assembly during erection at site. also at every 5 cm apart two nos steel rivet is required to be provide on galvanized steel tube ( for preventing the galvanized steel tube from coming out from each discharge rod pole end). i.e. about 08 nos. or more steel rivet as required per galvanized steel tube is to be provided for proper fastening of galvanized steel tube inside the each pole of discharge rod. (warranty period- 30 months after the date of delivery). [ warranty period: 30 months after the date of delivery ]
 Loading, Please wait...

Connect us via What's Up